摘要:在喷雾加湿工况下,对纺织空调系统所用的JYPW-1型喷雾轴流通风机的流量、全压、全压效率、轴功率和比A声级噪声等性能参数随喷淋水气比的变化进行了测试,得到了喷雾风机性能参数随水气比变化的曲线,并整理出喷雾风机在不同水气比时,其气动性能的近似计算公式,可供喷雾风机选型和工程应用时参考。
关键词:轴流式通风机 喷雾式 性能参数
中图分类号:TH432.1 文献标识码:B 文章编号:1006-8155(2005)05-0005-03
Abstract: Under spraying humidification state, the parameters of JYPW-1 spraying axial fans for textile enterprises such as flow, total pressure, efficiency, shaft power and acoustic power level changing with water-air ratio were tested, and the performance parameter curve changing with water-air ratio was obtained. The approximate formula of its pneumatic performance in different water-air ratio condition were deduced which can be referenced for of selection and project application. Key Words: Axial Fan Spray Performance parameter
1 引言
喷雾轴流通风机是在普通轴流通风机的轮毂内设计安装了机械雾化装置,使通风机具有送风和加湿的双重作用,相比较传统空调室而言,可取得相当可观的经济效益。传统的空调室采用喷嘴喷淋成水雾来对空气进行加湿,而喷嘴喷出水雾需要一定的水压,同时所需水量也较大(其水气比为μ=0.4~0.8),因而其结构复杂、耗能耗水量大;另外,由于喷嘴孔径小,容易堵塞,其维护检修费用高。以喷雾轴流通风机为核心设备的空调室,由于喷雾风机具有送风加湿的能力,从而简化了喷嘴、喷淋排等构件;由于喷雾风机雾化效果好,与空气的热湿交换效率较高,水气比较低(其水气比为μ≤0.1);同时喷雾风机成雾是利用了风机负压及离心力的作用,对供水不需压力,采用小流量的水泵即可,从而简化了空调室,节约用水、节省能耗,雾化装置不堵塞,维修方便。目前,国内生产的PWF-11/12型喷雾轴流通风机以及江阴市宏达风机公司研制的JYPW-1型大风量高效低噪喷雾风机在纺织企业空调室得到了广泛应用。 目前,在国内生产的喷雾轴流通风机产品技术说明中,给出的均是该类型风机在风机标准进气状态下的性能参数,即风机进口处的空气压力为101325 Pa,温度为20℃,相对湿度为50 %,空气密度为1.2 kg/m3时的性能参数值。而喷雾风机通常在喷雾加湿的情况下运转,是典型的气液两相流动,风机进口往往不是标准进气状态。风机的气动性能,诸如流量、全压、全压效率、轴功率及风机噪声,都会随着风机喷雾加湿状态下的水气比而改变。目前国内的风机生产企业,都没有给用户提供在喷雾加湿的情况下,喷雾风机气动性能随水气比的变化规律,这给用户造成了喷雾风机的选型和使用的困难。
笔者对JYPW-1型喷雾轴流通风机进行了喷雾加湿工况下不同水气比时的气动性能试验,发现随着水气比的增加,风机流量、全压、全压效率均有所降低,而风机轴功率增加,风机噪声则变化不大。根据气动性能试验结果,整理出喷雾轴流风机的流量系数、全压系数、全压效率和功率系数随水气比变化的近似计算公式,并经过实际计算验证了该近似计算公式的计算偏差较小,既符合JYPW-1型喷雾轴流通风机的使用要求,也同样适用于PWF-11/12型喷雾轴流通风机,可方便用户在喷雾轴流通风机选型和应用时参考。
2 加湿工况下喷雾轴流通风机的性能测试
JYPW-1型喷雾轴流通风机的结构如图1所示,由集流器、叶轮、机壳、底座、传动组件以及机械雾化器、回水筒体、进水组件等组成。叶轮为整体结构,叶片为采用优化气动设计方法设计的高效率低噪声机翼型扭曲叶片,材质选用高强度ZL104铸造铝合金,并经表面硬质氧化处理。叶轮采用锥度定紧套固定,装卸方便。机械雾化器是安装在叶轮轮毂内的特殊装置,由进水管、存水套、挡水盘及疏水栅等组成。 |